<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom"><title>ICY commercial building science</title><id>https://icy.ac/science/</id><link rel="self" href="https://icy.ac/feed.xml"/><link href="https://icy.ac/science/"/><updated>2026-10-06T00:00:00Z</updated><entry><title>Why a Building Stays Hot: A Heat-Balance Primer</title><id>https://icy.ac/science/heat-balance/</id><link href="https://icy.ac/science/heat-balance/"/><updated>2026-10-06T00:00:00Z</updated><summary>Follow heat entering, accumulating in and leaving a building before treating a hot-space complaint as an equipment-size decision.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Dew Point, Surface Temperature and Condensation</title><id>https://icy.ac/science/dew-point-condensation/</id><link href="https://icy.ac/science/dew-point-condensation/"/><updated>2026-10-06T00:00:00Z</updated><summary>Understand why relative humidity alone cannot predict condensation and how moisture, air pathways and cold surfaces interact.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Sensible and Latent Cooling: Temperature Is Only Part of the Load</title><id>https://icy.ac/science/sensible-latent-cooling/</id><link href="https://icy.ac/science/sensible-latent-cooling/"/><updated>2026-10-06T00:00:00Z</updated><summary>Separate temperature reduction from moisture removal when evaluating comfort, coil performance, runtime and ventilation load.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Airflow and Building Pressure: Follow the Complete Path</title><id>https://icy.ac/science/airflow-building-pressure/</id><link href="https://icy.ac/science/airflow-building-pressure/"/><updated>2026-10-06T00:00:00Z</updated><summary>Trace supply, return, outdoor air, exhaust and leakage as one mass-balance system instead of treating a door or grille symptom in isolation.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Temporary Cooling Works Only When Heat Leaves the Boundary</title><id>https://icy.ac/science/temporary-cooling-heat-rejection/</id><link href="https://icy.ac/science/temporary-cooling-heat-rejection/"/><updated>2026-10-06T00:00:00Z</updated><summary>Evaluate the cold side, hot side, replacement air, condensate and electrical input before calling portable cooling a net building solution.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Cooling Capacity and Efficiency Are Different Questions</title><id>https://icy.ac/science/cooling-capacity-efficiency/</id><link href="https://icy.ac/science/cooling-capacity-efficiency/"/><updated>2026-10-06T00:00:00Z</updated><summary>Read equipment ratings in context and separate heat-removal rate, electrical input, part-load behavior and installed delivery.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Measurement Uncertainty: Report What the Reading Can Support</title><id>https://icy.ac/science/measurement-uncertainty/</id><link href="https://icy.ac/science/measurement-uncertainty/"/><updated>2026-10-06T00:00:00Z</updated><summary>Define the measurand, preserve operating context and report instrument, sampling and calculation limits instead of false precision.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry><entry><title>Commissioning and Verification: Prove the Intended Operation</title><id>https://icy.ac/science/commissioning-verification/</id><link href="https://icy.ac/science/commissioning-verification/"/><updated>2026-10-06T00:00:00Z</updated><summary>Turn requirements into functional tests, acceptance evidence, corrections and repeatable records across the operating modes that matter.</summary><author><name>Gulf Coast Technologies, LLC</name></author></entry></feed>
