COMMERCIAL BUILDING SCIENCE · HEAT · AIR · MOISTURE · MEASUREMENT

Open commercial building science

Follow the heat, air and moisture—then measure what changed.

ICY turns established building physics into plain field questions. The library separates published science from GCT's practical measurement sequence, identifies uncertainty and leaves site-specific conclusions to actual evidence and qualified authority.

Educational material is not a remote diagnosis, load calculation, engineering design, code determination or authorization for regulated work.

01

Mechanism

Explain the physical process in ordinary language without pretending one mechanism proves the condition at a particular site.

02

Measurement

Name the reading, location, operating state, time and comparison needed to test the working explanation.

03

Limits

State what the readings cannot establish alone, including cause, responsibility, code compliance and equipment-specific diagnosis.

04

Sources

Connect the claim to primary technical material and record when the source link was reviewed.

Eight connected guides

Start anywhere. Keep the whole building in view.

The articles use SI units first and add U.S. customary equivalents where they improve field use. Terms link back to one shared glossary.

01 · Source-backed guide

Why a Building Stays Hot: A Heat-Balance Primer

Follow heat entering, accumulating in and leaving a building before treating a hot-space complaint as an equipment-size decision.

Read the guide →
02 · Source-backed guide

Dew Point, Surface Temperature and Condensation

Understand why relative humidity alone cannot predict condensation and how moisture, air pathways and cold surfaces interact.

Read the guide →
03 · Source-backed guide

Sensible and Latent Cooling: Temperature Is Only Part of the Load

Separate temperature reduction from moisture removal when evaluating comfort, coil performance, runtime and ventilation load.

Read the guide →
04 · Source-backed guide

Airflow and Building Pressure: Follow the Complete Path

Trace supply, return, outdoor air, exhaust and leakage as one mass-balance system instead of treating a door or grille symptom in isolation.

Read the guide →
05 · Source-backed guide

Temporary Cooling Works Only When Heat Leaves the Boundary

Evaluate the cold side, hot side, replacement air, condensate and electrical input before calling portable cooling a net building solution.

Read the guide →
06 · Source-backed guide

Cooling Capacity and Efficiency Are Different Questions

Read equipment ratings in context and separate heat-removal rate, electrical input, part-load behavior and installed delivery.

Read the guide →
07 · Source-backed guide

Measurement Uncertainty: Report What the Reading Can Support

Define the measurand, preserve operating context and report instrument, sampling and calculation limits instead of false precision.

Read the guide →
08 · Source-backed guide

Commissioning and Verification: Prove the Intended Operation

Turn requirements into functional tests, acceptance evidence, corrections and repeatable records across the operating modes that matter.

Read the guide →

Use, verify and reuse the map

The library includes human-readable and machine-readable paths.

Read the terms, inspect the official sources, download a blank field record, review the editorial method or use the JSON library map and plain-text discovery file.